IN STOCK IRAQ WAREHOUSE (ERBIL / BAGHDAD) | IP67 Environmental Protection | COSQC IRAQ VERIFIED
ta-0-50kg Load Cells (Tab 1) TAB-1

ta-0-50kg Tank & Vessel Weighing Module Load Cell 50 kg

Chemical reactor tanks, mixing vessels, brewery tanks, pharmaceutical hoppers.

HARDWARE OPTICAL VIEW 50 kg
ta-0-50kg Tank & Vessel Weighing Module Load Cell 50 kg 50 kg IP67 Environmental Protection
Metrological Verification: OIML Class III
Nominal Capacity
50 kg Calibrated batching capacity
Ingress Protection
IP67 Environmental Protection CIP washdown resistant
Safe Overload
150% FS Agitation shock margin
Ultimate Breakload
250% FS Structural vessel safety
Accuracy Class
OIML Class III OIML Class III verified
Operating Temp
-20°C to +70°C Vessel heat compensated
Chassis Material
Stainless Steel with Cast Mount Assembly 304/316 Stainless / Cast Mount
Combined Error
≤ ±0.03% FS Non-linearity + hysteresis

Precision Metrology & Electrical Specifications

SPEC VERSION: 2026.1 / CALIBRATION VERIFIED
Scroll table horizontally to view complete data
Structural Architecture Tank & Vessel Compression Module
Calibrated Rated Capacity 50 kg
Rated Output / Sensitivity 2.0 ± 0.01 mV/V
Combined Total Error ≤ ±0.03% FS
Bridge Input / Output Impedance Input: 385 ± 15 Ω | Output: 350 ± 5 Ω
Insulation Resistance ≥ 5000 MΩ (Tested at 50V DC)
Excitation Supply Voltage 10V DC
Compensated Temperature Range -20°C to +70°C
Safe / Ultimate Overload Margins Safe: 150% FS | Ultimate: 250% FS
Integral Cable Specification 4.0m Polyurethane Cable

ta-0-50kg: Vessel Geometry, Thermal Expansion & Anti-Lift-Off Architecture

Tank & Vessel Module Architecture
ta-0-50kg Structural Metallurgy & Materials

Stainless Steel with Cast Mount Assembly. Specifically engineered for Tank & Vessel Compression Module in Chemical reactor tanks, mixing vessels, brewery tanks, pharmaceutical hoppers.

  • Heavy cast-mount or machined base assembly evenly distributes concentrated vessel leg loads over supporting steelwork.
  • Corrosion-resistant metallurgy prevents degradation from caustic CIP cleaning solutions and aggressive chemical vapours.
  • Integrated lift-off jack screws permit load cell replacement or inspection while the vessel remains filled.
Ingress Sealing & Washdown Protection (IP67 Environmental Protection)

Certified IP67 Environmental Protection moisture barrier engineered for food, chemical, and pharmaceutical environments.

  • Resilient to high-pressure CIP (Clean-In-Place) washdown sprays and continuous surface condensation.
  • Polyurethane jacketed cable (4.0m Polyurethane Cable) with internal water-blocking barrier prevents capillary fluid migration.
  • Operating temperature range of -20°C to +70°C handles steam sterilization without zero balance shift.

Vessel Expansion Management & Agitation Stability

Built-in anti-lift-off hardware prevents tank tipping under high winds and agitation.

Radial Thermal Expansion Accommodates up to ±8mm thermal expansion and contraction during steam cleaning or heated liquid cycles.
Anti-Tipping Restraint Captive top-plate bolts securely retain empty silos and outdoor vessels against 120 km/h Iraqi dust-storm crosswinds.
Elimination of Stay Rods Integral horizontal side-stops absorb mixer impeller torque and seismic impulses, eliminating complex external tie-rods.

ta-0-50kg: 4-Wire Wheatstone Bridge Pinouts & Process Batching Interfacing

Hardware Interface Map
Standard 4-Wire Wheatstone Bridge Conductor Code
RED + Excitation Supply (+Exc): 10V DC
BLACK - Excitation Return (-Exc)
GREEN + Signal Output (+Sig): 2.0 ± 0.01 mV/V
WHITE - Signal Return (-Sig)
YELLOW Braided Outer Shield / Vessel Equipotential Bond
Industrial Automation & PLC Integration
  • Bridge Impedance: Input 385 ± 15 Ω | Output 350 ± 5 Ω ensures fast, stable signal resolution.
  • PLC Analog Interfacing: Compatible with 4–20mA / 0–10V DIN-rail signal conditioners for Siemens, Allen-Bradley, and Delta PLCs.
  • Parallel Summing: Direct connection to multi-cell summing junction boxes with corner trim for circular vessels.
  • Dynamic Agitator Filtering: Optimized for digital low-pass filtering to cancel liquid sloshing and mixer blade vibration.
Electrical Welding & Equipotential Grounding Advisory: Prior to performing any arc welding on vessel walls, agitators, or connecting pipework, install a heavy flexible copper shunt braid across ta-0-50kg to prevent welding current from destroying the internal strain gauge foil.

ta-0-50kg: Regional Field Performance Across Iraq & Process Industry Rigor

COSQC Legal Verification
Southern Iraq (Basra & Khor Al-Zubair)

High humidity and petrochemical vapors at fertilizer and plastics plants require stainless modules to resist sulfurous atmospheric corrosion and saline coastal mist.

Central Iraq (Baghdad & Karbala)

Bitumen, asphalt, and food syrup storage tanks frequently reach elevated temperatures. Heavy thermal insulation decoupling pads isolate module sensors from conductive heat.

Kurdistan Region (Erbil & Sulaymaniyah)

Flour mills, beverage bottling plants, and grain silos in Bazian and Erbil industrial zones require sanitary washdown construction and high wind-shear survival.

Iraqi COSQC Legal Metrology Compliance for Batching Instruments

Compliant with COSQC and OIML R61 / R76 regulations for trade-approved automatic gravimetric filling instruments and industrial process hoppers.

OIML R60 / R76 Metrological Verification CIP Food & Chemical Hygiene Compliance Bwer On-Site Vessel Calibration Available

Need Detailed CAD Dimensions & Technical Drawings?

We provide dimensional 2D AutoCAD (.DWG), 3D STEP models, and full PDF wiring schematics for engineers and electrical panel integrators.

Request CAD & Wiring Diagram
RELATED HARDWARE

Similar Load Cells (Tab 1) Inventory

View All 52 Components
8-2a25t 25 Ton (25,000 kg)
8-2a25t
8-2b22t 22 Ton (22,000 kg)
8-2b22t
ac-1a-25t 25 Ton (25,000 kg)
ac-1a-25t
ac-2a-25t 25 Ton (25,000 kg)
ac-2a-25t
Get In Touch

Consult With Our Weighbridge Engineers

Contact our engineering department today for customized advice, foundation drawings, and transparent pricing tailored to your site.

60-Minute Response Guarantee
Free AutoCAD Foundation Drawings
Iraqi COSQC Certified Partner

Hızlı Mühendislik Fiyat Teklifi

Teknik şartname, temel projesi ve şeffaf fiyatlandırma 60 dakika içinde

🔒 %100 Gizlilik Garantisi • Resmi Üretici Güvencesi • Taahhütsüz Danışmanlık

Direct Engineering Line

24/7 Acil Teknik Hat
+964 770 654 5544

Tüm Irak vilayetlerinde kıdemli kantar mühendisleri ile doğrudan iletişim

Anında WhatsApp Danışmanlığı

Instant
+9647706545544

AutoCAD temel projeleri, fiyat listeleri ve teknik kataloglar hemen cebinizde

Main Offices

Iraq Nationwide
Bağdat (Merkez): Industrial Area, Iraq
Kürdistan & Kerkük: Kalar / Sulaymaniyah Highway
Basra & Güney: Logistics & Port Services

Gezici mühendislik ve kalibrasyon ekiplerimiz Irak genelinde 24-48 saatte sahada